Ambient Bimetal

Aplications
The ambient thermostat is mainly used to control the temperature of electric heaters, convectors, heat fans, oil heaters. It is used to ensure the room temperature does not go over 180º C

Operation
The temperature is adjusted by the rotation of the device's axis. When the desired temperature is reached, the contacts are quickly opened due to the deflection of the bimetallic strip, interrupting the circuit's power supply. When the temperature drops, the contacts are closed and the circuit starts to operate again.

 



Thermal:

Range of temperatures:
Up to a maximum of 70 °C
Cutting tolerance: +/- 3 K
Differential: 4 °C; +/- 2 K
Rotation range: 300 °


Electrical:

Electrical conduction
capacity:

16 A to 250 V
10 A to 380 V
15 A to 120 V